裝配圖XY-4巖心鉆機升降機的設計
裝配圖XY-4巖心鉆機升降機的設計,裝配,xy,巖心,鉆機,升降機,設計
Journal of Stored Products Research 42 (2006) 226–239 during 1999 and 2000. Five locations per elevator were observed; the boot pit, dump pit, headhouse, rail ARTICLE IN PRESS $ This study reports the results from research only. No recommendations are given or implied by the US Department of Agriculture, Kansas State University, or Oklahoma State University. C3 0022-474X/$-see front matter r 2005 Elsevier Ltd. All rights reserved. doi:10.1016/j.jspr.2005.02.003 Corresponding author. Tel.: +17857762783; fax: +17857762792. E-mail address: arthur@gmprc.ksu.edu (F.H. Arthur). area, and tunnel. When a grain residue was found, the quantity was estimated and a sample taken. Adult grain pest insects and beneficial insects were removed and identified. Cryptolestes spp. and Sitophilus spp. comprised about 80% of the pest insects collected. The density of Cryptolestes spp. appeared to rapidly increase in spring but remained low at other times of the year. The density of Sitophilus spp. in the residues increased consistently through the warm months, peaked immediately after the warmest month, and declined gradually as ambient temperatures cooled. Pest insects were observed in 41.7% of the 1575 samples examined, and beneficial insects were collected from 5.1% of the samples. Residue samples taken from the elevator boot pit and tunnel areas contained a greater density of pest insects (all species combined) than other locations. About 42% of the residues were estimated to be smaller than 1.5kg, and samples from these residues contained more insects per sample than did samples from larger residues. Anisopteromalus calandrae comprised 88.9% of the total number of beneficial insects found. Beneficial insects were observed infrequently, and mean populations exceeded 1insect/kg of residue in any month at only two of the nine elevators. Results from our study showed that grain residues within the elevator often contain pest insects Insect populations in grain residues associated with commercial Kansas grain elevators $ Frank H. Arthur a,C3 , David W. Hagstrum a , Paul W. Flinn a , Carl R. Reed b , Thomas W. Phillips c a Grain Marketing and Production Research Center, USDA-ARS, 1515 College Avenue, Manhattan, KS 66502, USA b Department of Grain Science and Industry, Kansas State University, Manhattan, KS, USA c Department of Entomology, Oklahoma State University, Stillwater, OK, USA Accepted 18 February 2005 Abstract Grain residues in nine commercial elevators in Kansas were sampled monthly for insects in grain residues 60-day incubation period. ARTICLE IN PRESS F.H. Arthur et al. / Journal of Stored Products Research 42 (2006) 226–239 227 In a recent survey of insects collected from grain in the bottom of elevator silos and from discharge spouts (Reed et al., 2003), Cryptolestes spp., Rhyzopertha dominica (F.), Oryzaephilus spp., Tribolium spp., and Sitophilus spp. weevils were observed consistently over a 2.5-year period. In the discharge spouts, Cryptolestes spp. comprised 65% or more of the insects collected in four of the five sampling periods (6 months each). Rhyzopertha dominica comprised about 10% of the population most of the time, and Sitophilus spp. comprised from 3.9 to 23.3% of the and could provide food and harborage when the bins are empty, serving as sources of insect infestation for new grain. r 2005 Elsevier Ltd. All rights reserved. Keywords: Sanitation; Cleaning; Elevators; Grain; Insects 1. Introduction In the central plains region of the United States, stored-grain insects can quickly infest newly harvested grain in farm bulk bins (Hagstrum, 1987, 1989; Reed et al., 1991; Dowdy and McGaughey, 1994; Hagstrum et al., 1994; Vela-Coiffier et al., 1997; Hagstrum, 2001). A likely source of this infestation is residual grain inside the bins, which can be heavily infested with stored-grain insects (Ingemansen et al., 1986; Loschiavo and Smith, 1986; Barker and Smith, 1987, 1990). Sanitation practices such as removing grain residues from inside bins and applying bin sprays are often recommended for farm-stored hard red winter wheat in the south-central US (Reed and Pedersen, 1987; Reed and Harner, 1998; Reed et al., 1990; Cuperus et al., 1990). Nevertheless, Herron et al. (1996) found little correlation between hygiene practices and infestations inside farm bins in Australia. Furthermore, Reed et al. (1990) showed that there was no economic incentive for using insecticides as pre-binning sprays to eliminate residual populations inside empty bins, even when these sprays appeared to be effective. Grain in commercial elevators can become infested with insects quickly, as illustrated by a study of 13 elevator sites in Kansas (Reed et al., 2001). Pitfall traps placed in wheat immediately after storage in these elevators detected insects in half the silos within two weeks. In warm climates, stored-grain insects are known to infest crops in the field (summarized by Reed et al., 2003). However, in climatic zones similar to those of the present study, sampling of new grain delivered directly from the field has given little indication of infestation (Chao et al., 1953; Hagstrum et al., 1995; Vela-Coiffier et al., 1997). In elevators, it appears likely that a major source of the insects that infest new grain is previously infested grain present when the new crop is received. Other likely sources are infested grain residues in empty bins, spills and other related debris in and around elevators. It is also possible that trucks and railcars used to transport grain to commercial elevators may be infested. Dowdy and McGaughey (1996) surveyed four elevators in Kansas and consistently detected insects in the elevator base areas, dump pits, head houses, on the top of the elevators, silo head spaces, and outside areas. They also sampled residual material containing grain dust and did not find insects upon initial examination, but did collect some insects (primarily dermestids) after a insects collected, depending on the sampling period. In the grain remaining inside empty bins, Cryptolestes spp. comprised 45%, Sitophilus spp. represented 32.4%, and R. dominica comprised 9% of the insects collected. Two of the grain elevators reported in Reed et al. (2003) were sampled in the present study. Most research on insects in grain residues found outside of storage bins has been conducted at farm sites, and there is comparatively little research in large commercial grain elevators. Spilled grain and other residual grain materials in and around elevators but outside the storage bins may also contain resident insect populations, and represent an important source of infestation for new grain. There are few published data regarding the composition and abundance of insects in grain residues found inside elevators. The purpose of this study was to determine: (1) species composition of insects collected from grain residues in commercial elevators but outside the storage bins; and (2) distributional and seasonal density patterns of these populations. 2. Materials and methods Nine elevators in Kansas with concrete silos were visited monthly in 1999 and 2000 to inspect for accumulations of spilled grain or grain residue, including broken grain, grain dust, and plant trash. A few visits (3% of samples) were made in January and February of 2001. Although visits ARTICLE IN PRESS F.H. Arthur et al. / Journal of Stored Products Research 42 (2006) 226–239228 Annex Dump Pit Elevator Boot Tunnel Headhouse were made monthly, the actual amount of grain varied depending on the time of year and frequency of grain movement through the elevator. Similar difficulties were noted in an earlier study by Reed et al. (2003). Grain residues were recorded as being in or close to one of the following locations: elevator boot, tunnel, truck dump, rail line, ground-level areas of the headhouse, or bin-deck level of the headhouse or annex (Fig. 1). The elevator boot is the enclosed base of the elevator leg, and is located in the basement or in a sub-basement pit. The tunnel houses the reclaim conveyor beneath the annex bins. The truck dump is the area above the dump pit Elevator Leg Fig. 1. Illustration of the inspection and sampling locations in grain elevators. ARTICLE IN PRESS where grain enters the elevator from trucks. The rail load area usually is a covered part of the railroad track that passes close to the elevator. Samples collected on the rail line, including those collected in the rail load area, were designated as rail line samples. The main elevator legs are housed in the headhouse. The roof of the grain storage bins forms the floor of the bin-deck level of the headhouse and annex(es). The bin-deck level contains spouts that transport the grain from the elevator leg to the bins or to lateral conveyors. Elevator boot areas and boot pits are often damp and the temperature in them is moderated by the subterranean location. Spills and residues in this area result from clean-out of the elevator boot (rare) or spills from worn spouts. Spills in the tunnel area are often exposed to water from leaks in the wall or floor, and the temperature in the tunnel is moderated by its subterranean location. The pit of the truck dump is nearly self-cleaning because most residues from a previous load are flushed when new grain is subsequently moved through the pit. However, spills often occur around the dump pits; these residues are exposed to ambient air. The railroad line is outside the facility and is usually covered by a roof where it passes over the dump pit. Spills on the rail line are often the result of railcar clean-out. Residues in the headhouse ground level consisted of spills from worn grain spouts. Spills on the bin-deck level may be due to worn spouts or spills from the conveyor belt. Typically, they are exposed to ambient conditions. The amount of grain residue was recorded monthly for each elevator. Quantities of residues were estimated by the sampler as either p1.5kg, 41.5kg p27kg (about one bushel), 1.5kgp27kg (5bu), and 4135kg. Samples of the residues were collected as randomly as possible. When the quantity of residue was small, it was brushed into a dustpan and placed in a sample bag. When a large amount of residue or spillage was present, several kg samples were collected from different locations and placed in labeled sample bags. Samples were transported to the laboratory, where they were weighed and characterized as to grain type. Extremes of heat or cold were avoided during sample transport and the samples were stored at room temperature for a maximum of five days before analysis. To facilitate accurate identification of insects, each sample was sieved through various wire- mesh screens to separate as much as possible the live insects from the grain and trash. Adults of Typhaea stercorea (L.), hairy fungus beetle; R. dominica; and Ahasverus advena (Walt.), foreign grain beetle were identified to species. Adults of the following were identified to genera because closely related species are sometimes found in stored grain: Sitophilus, Cryptolestes, Tribolium, and Oryzaephilus. Adults of the four parasitoid wasps Habrobracon ( ? Bracon) hebetor (Say), Anisopteromalus calandrae (Howard), Theocolax ( ? Choetospila) elegans (Westwood), and Cephalonomia waterstoni (Gahan) also were identified to species. Data for the two years in which these samples were collected were combined and the Statistical Analysis System (SAS Institute, 2001) was used to analyze these data. Raw data were transformed using the square root in an attempt to normalize variances for purposes of means-testing, but non- transformed means and other statistics are reported here to facilitate intuitive interpretation. Insect density is reported as the number of live adult insects per kg of residue. The general linear models (GLM) procedure was used to determine the significance of various factors with respect to insect distribution. When a significant model effect was observed, means were separated using the Waller/Duncan k-ratio t-test. The correlation procedure (CORR) was used to correlate numbers of beneficial insect species with those of their primary host among the pest insect species. The F.H. Arthur et al. / Journal of Stored Products Research 42 (2006) 226–239 229 frequency procedure (FREQ) was used for categorical analysis and w 2 tests. ARTICLE IN PRESS F.H. Arthur et al. / Journal of Stored Products Research 42 (2006) 226–239230 3. Results In total, 46,725 pest insects and 933 beneficial insects were collected and identified from 1575 grain residue samples. The mean sample size was 559.6712.5g (SE) of grain residue. The mean insect population density varied from 16.5 to 66.2/kg between individual grain elevators (Table 1), but means were not significantly different because variability was great. Because there was no significant relationship (r ?C00:28, P ? 0:42) between the storage capacity of the elevator and the insect density (all species combined), data from all elevators were combined for further analysis. The predominant insect species in all residue samples were Sitophilus spp. and Cryptolestes spp., comprising 50.3% and 30.7%, respectively, of the total number of insects collected. In the majority of the residue samples (58.3%) no pest insects were found. Of the samples in which pest insects were found, 3.2% contained p1 insect/kg, 44.7% contained 41 insects p10/kg, 39.6% contained 410 p100 insects/kg, and 12.5% contained 4100 insects/kg. The highest density of pest insects (all species) and of Sitophilus spp. in particular was found in the smallest residues (o1.5kg) compared with the other three size categories (Table 2). The density of the other insect species did not differ significantly by estimated size of the residue. Samples from residues found in or near the elevator boot pit and tunnel contained higher insect densities than did residues from the dump pit, headhouse, or rail line (Table 3). This relationship was true for each of the dominant species individually. For example, the density of both Sitophilus spp. and Cryptolestes spp. was more than four times greater in samples from or near the boot pit than in samples from the dump pit, headhouse areas or on the rail line. Density of Tribolium spp. in samples from the boot pits and tunnels was at least twice as great as from any of the other locations. Samples identified as wheat were the most common type (42.8%). Other residue samples were identified as maize (17.7%), sorghum (14.0%), a mixture of wheat and sorghum (3.4%) or a mixture of maize, wheat, and sorghum (14.1%). About 8.4% were called ‘‘other’’ because the material consisted of uncommon mixtures of grains and dust. Mixtures of wheat and sorghum had a greater density of Sitophilus spp. and all species combined than did samples of either sorghum or wheat individually, and the population density of Tribolium spp. was lowest in residues that contained only sorghum (Table 4). The density of Sitophilus spp. was markedly different in residues of different grains, with an average of nearly 31/kg in wheat–sorghum mixtures but less than 7/kg in sorghum residues. The density of Tribolium spp. also was significantly affected by the composition of the residue. Of the species present in high numbers, only the density of Cryptolestes spp. was not affected by type of grain in the residue sample (Table 4). Of the insects found only in low numbers, a significantly higher density of T. stercorea was found in the samples classified as a mixture of wheat, maize, and sorghum than any other type of sample. The mean density of T. stercorea, R. dominica, A. advena, and Oryzaephilus spp. in the residue samples did not exceed 2 insects/kg regardless of the time of year (Fig. 2A–D). Numbers of T. stercorea peaked in April and September, the beginning and the end of the warm season, and were low at other periods. Densities of Oryzaephilus spp. also showed two peaks, in June and October. In contrast, the greatest densities of R. dominica were observed in three consecutive winter months. The density of Sitophilus spp. was 45 insects/kg in the residue samples throughout the year except for the coldest winter months, which suggests that low temperatures ARTICLE IN PRESS Table 1 Density of live adult pest insects per kilogram (mean 7 SE) from residues collected over all sampling times, percentage of residue samples infested with pest insects, and total number of samples and adult live beetles of each species, by elevator (Elev.) Elev. n a Sitophilus Cryptolestes Tribolium Typhaea stercorea Rhyz opertha dominica Oryzaephilus Ahasverus advena Total % Infested A 6 4 5.94 7 4.02 16.52 7 9.28 1.66 7 1.19 0.00 7 0.00 0.27 7 0.16 0.08 7 0.08 0.00 7 0.00 24.47 7 11.68 43.8 B 9 4 17.05 7 6.87 0.87 7 0.40 0.86 7 0.52 0.07 7 0.07 0.32 7 0.17 0.32 7 0.23 0.19 7 0.11 19.68 7 7.09 30.8 C 124 31.28 7 12.59 6.22 7 1.88 2.51 7 0.87 0.04 7 0.03 0.09 7 0.04 0.28 7 0.10 0.05 7 0.05 40.45 7 13.86 47.6 D 152 13.45 7 3.36 51.33 7 33.65 0.53 7 0.20 0.25 7 0.09 0.50 7 0.19 0.03 7 0.02 0.04 7 0.03 66.15 7 35.71 46.7 E 192 7.91 7 3.23 17.31 7 8.28 2.58 7 1.99 0.12 7 0.08 0.97 7 0.47 0.14 7 0.10 0.33 7 0.33 29.35 7 9.85 41.7 F 174 12.04 7 3.78 5.38 7 2.11 2.22 7 0.89 0.17 7 0.09 0.09 7 0.08 0.24 7 0.10 0.03 7 0.02 20.18 7 5.74 44.8 G 186 29.15 7 7.25 6.04 7 1.62 14.60 7 10.74 0.13 7 0.10 0.04 7 0.03 0.28 7 0.13 0.14 7 0.10 50.37 7 13.85 54.8 H 311 4.79 7 1.88 5.20 7 1.75 4.17 7 2.38 0.92 7 0.64 0.08 7 0.52 0.55 7 0.42 0.04 7 0.04 16.48 7 4.99 37.3 I 278 11.29 7 3.44 0.89 7 0.29 3.28 7 2.32 0.05 7 0.03 0.17 7 0.11 0.81 7 0.57 0.03 7 0.02 16.52 7 4.33 33.8 Total 1575 21,570 16,960 6384 428 644 591 144 46,725 a n ? number of samples. Table 2 Number of live adult insects a per kg (mean 7 SE) and percentage of residue samples infested with pest insects, by estimated size of residue Residue size (Kg) Sitophilus Cryptolestes Tribolium Typhaea stercorea Rhyzopertha dominica Oryzaephilus Ahasverus advena Total % Infested o 1.5 19.36 7 3.31a 16.46 7 7.34a 6.40 7 3.06a 0.30 7 0.18a 0.39 7 0.12a 0.46 7 0.22a 0.15 7 0.09a 43.52 7 9.17a 44.0 1.5–27 9.83 7 2.15b 3.83 7 0.89a 3.07 7 1.44a 0.38 7 0.33a 0.53 7 0.33a 0.47 7 0.30a 0.07 7 0.04a 18.16 7 3.23b 40.5 27–135 10.19 7 3.11b 9.46 7 5.23a 0.74 7 0.25a 0.07 7 0.04a 0.20 7 0.11a 0.14 7 0.07a 0.03 7 0.02a 20.84 7 7.44b 39.1 4 135 5.33 7 1.79b 8.42 7 6.23a 1.39 7 0.69a 0.10 7 0.06a 0.46 7 0.30a 0.06 7 0.04a 0.00 7 0.00a 15.78 7 7.28b 39.1 Data combined over all elevators and sampling visits, n ? 705, 482, 230, and 158 for each size category, from smallest to largest. Means within columns followed by the same letter are not significantly different ( P X 0 : 05, Waller–Duncan k -ratio t -test, SAS Institute). a ANOVA model significant with respect to total number of insects (PROC GLM, SAS Institute, F ? 6 : 2, df ? 3,1571, P o 0 : 01). F.H. Arthur et al. / Journal of Stored Products Research 42 (2006) 226–239 231 ARTICLE IN PRESS Table 3 Number of live adult insects a per kg (mean 7 SE) and percentage residue samples infested with pest insects, by inspection location Location Sitophilus Cryptolestes Tribolium Typhaea stercorea Rhyzopertha dominica Oryzaephilus Ahasverus advena Total % Infested Boot pit 40.08 7 7.90a 9.31 7 2.80ab 10.94 7 5.73a 0.14 7 0.06a 0.70 7 0.35a 1.23 7 0.56a 0.11 7 0.08ab 62.54 7 12.92a 71.1 Dump pit 8.52 7 1.54b 6.50 7 1.66bc 1.11 7 0.27b 0.43 7 0.29a 0.44 7 0.19a 0.14 7 0.04b 0.02 7 0.02b 17.16 7 2.56b 45.3 Headhouse 3.38 7 1.44c 6.88 7 2.74bc 1.47 7 0.48b 0.09 7 0.04a 0.23 7 0.08a 0.07 7 0.04b 0.01 7 0.01b 12.10 7 3.48b 29.7 Rail line 8.16 7 2.41b 2.61 7 1.42c 4.76 7 4.30b 1.17 7 1.07a 0.14 7 0.10a 1.01 7 0.95b 0.05 7 0.04b 17.89 7 5.96b 35.4 Tunnel 37.09 7 8.49a 33.97 7 20.94a 11.31 7 8.20a 0.01 7 0.01a 0.80 7 0.65a 0.67 7 0.54b 0.43 7 0.27a 84.28 7 25.24a 53.1 Data combined for all elevators and sampling visits n ? 142, 417, 626, 147, and 243 for each location from top to b
收藏